In this example,
- ADC inputs ANS1 and ANS2 are continuously scanned.
- EMIOS and the CTU areconfigured so an input signal on eMIOS channel 2 will cause an event that “cross triggers” a conversionfor ANS0.
- To generate an input signal, eMIOS channel 3 is configured for OPWM.
- Both channels useeMIOS channel 23 configured as modulus counter for their time base.
Exercise:
Make the connections shown below:
- Connect ANS0 to a potentiometer or a known voltage.
- Connect ANS1:2 to other known voltages.
- Verify the eMIOS channel 2 injects an ADC command which reads the pot value.
Connections:
SIGNAL ADC0_Channel PORT SIU_PAD_CONFIG PACKAGE_PIN(QFP/BGA) (100 144 176) ANS0 32 B8 PCR[24]=2000 39 53 R9 ANS1 33 B9 PCR[25]=2000 38 52 T9 ANS2 34 B10 PCR[26]=2000 40 54 P9 eMIOS0[2] - A2 PCR[2]=0503 5 9 F2 eMIOS0[3] - A3 PCR[3]=0600 68 90 K15 Connect Jumper between PA[2] and PA[3]
Program Outcome:
INPUT => OUTPUT ANS0 PB[8](CTU Inject Mode) (ADC0) => LED1 (ON if Input>=500, else OFF) ANS1 PB[9] (Normal Scan mode) (ADC0) => LED2 (ON if Input>=500, else OFF) ANS2 PB[10] (Normal Scan mode)(ADC0) => LED3 (ON if Input>=500, else OFF) [LED4 is Continuously Toggling (Blinking) to Check Whether Program is executing in Infinite Loop] eMIOS0_3 PA[3] Generates 1KHz with 25% Duty Cycle eMIOS0_2 PA[2] injects conversion at ANS0 (ADC0). (CTU is used)
Downloads:
ADC_CTU_TRK-MPC5606B_APDaga
Click here to see more codes for Freescale/NXP MPC56xx Family.
Feel free to ask doubts in the comment section. I will try my best to solve it.
If you find this helpful by any mean like, comment and share the post.
This is the simplest way to encourage me to keep doing such work.
Thanks and Regards,
-Akshay P. Daga